Universal turbo actuator II
Microsite Electronics
Universal turbo actuator II
Universal turbo actuator II

Universal turbo actuator II

ADVANTAGES
  • Variable nozzle turbine for diesel engines
  • HELLA CIPOS® sensor technology (contactless inductive position sensor)
  • Interface PWM, analog or SENT
  • Spur gear system for longer lifetime
  • Various attachment options (dimensions and angle bracket) 

IMPROVEMENTS ON THE 1ST GENERATION

  • Longer lifetime
  • Higher operating temperature
  • Lower weight
  • Lower costs

TECHNICAL DATA

Universal manifold actuator
Universal turbo actuator II
DC motor test voltage UT = 14 V ± 0.2 V
Voltage range (operation) 9 V - 16 V
Temperature range (operation) -40°C to +160°C
Min. torque (up to 0.2°/ms) after lifetime ≥ 55 Ncm (160°C)
Rated speed (25 Ncm, RT) 1.3°/s
SOP 2016