In this database, you will find technical information on our products and certain vehicle systems – compiled by experienced technicians and mechanics. You can search the database by entering multiple keywords, for instance the product, relevant system or components, and also filter the information using the categories (for example, lighting, electronics, etc.).
"1 © Hella KGaA Hueck & Co., Lippstadt/Germany 28. Oktober 2009 1-1 Technical Information Starters with flange seal Starters fitted to vehicles from the Ford Mondeo III and Transit series are sealed at the flange b"
"1 © Hella KGaA Hueck & Co., Lippstadt 30 March 2007 1-1 Technical Information Starters with oil contamination Pattern of damage A starter contaminated through oil can be recognized by oil deposits in the bearing bell an"
"1 © Hella KGaA Hueck & Co., Lippstadt 1 June 2007 1-1 Technical Information Alternator corrosion damage Damage Corrosion damage on alternators can be recognized via heavy corrosion on the contacts and on the connection "
"1 © Hella KGaA Hueck & Co., Lippstadt 3 May 2007 1-1 Technical Information Alternator oil-fouled Damage The entry of oil causes the formation of an oil film on the housing, the windings, the slip rings and the carbon bru"
"1 © Hella KGaA Hueck & Co., Lippstadt 3 May 2007 1-1 Technical Information Alternator bearing damage Damage The symptoms of bearing damage on alternators are heavy noise, radial or axial play in the rotor, or a blocked r"
"1 © Hella KGaA Hueck & Co., Lippstadt 20 November 2006 1-1 Technical Information Alternators with heavily oil-fouled vacuum pump Damage In the case of some vehicles with diesel engines, the vacuum required for the brake bo"
"1 © Hella KGaA Hueck & Co., Lippstadt 29 June 2007 1-1 Technical Information Alternator Damage due to short-circuit/polarity reversal Damage Damage due to short-circuits/polarity reversal on alternators can be recognize"
"1 © Hella KGaA Hueck & Co., Lippstadt/Germany 6. Mai 2010 1-2 Technical Information Throttle-valve housings General points Throttle valves are installed between induction bridge and load sensor. Throttle valves con"