Engine has no power
If a customer complains about the above problem, this could be caused by a defective camshaft actuator. Also, various fault codes are stored in the engine control unit in conjunction with variable valve timing. Further, unsteady idling and poor throttle response may also be complained about. But before replacing the actuator, you should carry out the following tests:
1. Turn off the ignition.
2. Remove the plug from the actuator.
3. Measure the resistance between the two contact pins. At 20°C, the following resistances should be measured.
· Siemens actuator 6.8 – 8.0 Ohm
· Denso actuator 6.9 – 7.9 Ohm
· Delphi actuator 6.7 – 7.7 Ohm
4. If the readings are not OK, the actuator must be replaced. If the readings are OK, remove the camshaft actuator and check it for mechanical damage. In some circumstances, metal debris may deposit in the actuator, making adjustments no longer possible (see figure). In this case, blow out the actuator with compressed air, for example.
Important safety notice
The following technical information and tips for practical use have been set up by HELLA in order to offer professional support to automotive workshops in their daily work. The information available here on this website is only to be used by appropriately trained specialist staff.
The reprinting, distribution, reproduction, exploitation in any form and disclosure of the contents of this document, even in part, is prohibited without our express written approval and indication of the source. The schematic illustrations, figures and descriptions are for explanation and presentation of the document text and cannot be used as a basis for installation or design. All rights reserved.