If it is reported that a large amount of effort must be expended to operate electric power steering for these vehicles, then the torque sensor for the electric power steering may be defective.
Check in advance whether error codes have been stored relating to the torque sensor for electric power steering.
In order to analyse the source of the error and to rule out other causes of the malfunction, the electrical connections and the contacts for the wiring harness multi-plug have to be checked (see Figure/arrows). Furthermore, ensure that the plug connectors are firmly seated on the wiring harness connectors.
If no malfunctions arise during the electrical analysis, then the gear rack for the electric power steering can be taken into consideration as the source of the error.
Important safety notice
The following technical information and tips for practical use have been set up by HELLA in order to offer professional support to automotive workshops in their daily work. The information available here on this website is only to be used by appropriately trained specialist staff.
The reprinting, distribution, reproduction, exploitation in any form and disclosure of the contents of this document, even in part, is prohibited without our express written approval and indication of the source. The schematic illustrations, figures and descriptions are for explanation and presentation of the document text and cannot be used as a basis for installation or design. All rights reserved.