In the VW T5 vehicle type, model year 2004, the problem of fogged windows may be caused by a faulty evaluation function of the air quality sensor.
Air quality sensor (figure).
The built-in evaluation electronics in the sensor module responds to changes in the conductivity of the sensor.
Due to the design, the function or the evaluation of the air quality sensor may be affected by the influence of spray or drip water in this type of vehicle. (The air quality sensor is located below the windshield in the region of the fresh air intake.)
Solution:
Check the function of the air quality sensor
Check the fuse 22
Install a spray and drip water deflector for the sensor.
Additional information for service:
According to information from the manufacturer, the air quality sensor is not subject to wear under normal conditions.
The combfilter (interior filter) should be replaced at service intervals.
Important safety note
Technical information and practical tips have been compiled by HELLA in order to provide professional support to vehicle workshops in their day-to-day work. The information provided on this website is intended for use by suitably qualified personnel only.
Reprinting, distribution, reproduction, exploitation in any form or disclosure of the contents of this document, even in part, is prohibited without our express, written approval and indication of the source. The schematic illustrations, pictures and descriptions serve only for the purposes of explanation and representation of the instructions and cannot be used as a basis for installation or assembly work. All rights reserved.
Not helpful at all
Very helpful